Skip to main content

Posts

Showing posts from May, 2009

Web-only Batch Versions

Hi   Web-Only versions is a workaround solution until full batch versions are available on the Web client and there is no longer a distinction between windows versions and web-only versions.   This functionality is available beginning with the 8.98_200 Series Tools Release for application release 8.12.  This application release 8.12 does require an ESU for SAR 8663474 TT-812 Enable Full BV on Web. This functionality is not available for earlier application releases.   Regards, JDEHelp This email may contain confidential or privileged information for the intended recipient(s). If you are not the intended recipient, please do not use or disseminate the information, notify the sender and delete it from your system. Thanks ______________________________________________________________________

Recompress Full Client Parent Package in E1 8.12 release

Hi   In E1 8.12 release, for integrity reasons, package revision is not allowed for deployed package s. The following steps can be performed to recompress a full client parent package : 1. Go to GH9083 then   Package build History Application (P9622). 2. Find the full client parent package and expand the package folder in the following manner:          Package name              -> Time and Date                       -> CLIENT                              ->Compression Options 3. Highlight the directory you want to compress and select Row Exit "Reset Status ". 4. In  Reset Build Status screen (W9622C), set both the "Spec Build Status " and "Pack Build Status " fields to      01 - Not Built. 5. Press the RESET button to save the changes. 6. Repeat steps 3 to 5 to select the directories that need to be recompressed.      Note: To recompress all directories under Compression Options, you can highlight on "Compression      Options" a

Solution for ER Debugger Issue(Debugger not working from web client)

Hi All   Please follow the steps as mentioned below to resolve ER debugger problem. Minimum requirements:- Install jdk-1_5_0_18-windows-i586-p.exe (Setup launcher) Restart the fat client and follow these steps. a) Steps to be followed while using ER Debugger:- 1)       Always take remote session by MSTSC /CONSOLE 2)       Before login into JDE fat client, go to Task Manager->Processes and check for java.exe and rdpclip .exe 3)       If processes java.exe and rdpclip.exe exists end these processes. 4)       Login to JDE fat client and open Debugger.exe from fastpath. 5)       If multiple objects are added then rebuild DIA for that object before debugging.   b) If Debugger doesn't work follow these steps:- 1)       Logout of JDE fat client. 2)       Go To Task Manager->Processes 3)       Delete processes java.exe and rdpclip.exe . 4)       Login to JDE fat client and can use debugger. c) Still if debugger doesn't work: - Contact your  CNC team. Regards,

Setup Security for the Universal Table Browser (UTB)

Security can be defined for the Universal Table Browser using External Calls security and Application security. To secure users from the Universal Table Browser: Within External Calls security, the user or role should be secured from access to the Universal Table Browser application UTBROWSE .exe.   A second option is within application security, the user or role should be secured from the P98TAM application.  This application is the application where users specify which table they wish to open within UTB. To grant access to the Universal Table Browser Within External Calls security, the user or role should be granted access to the Universal Table Browser application UTBROWSE .exe.  Then within application security, the user or role should be allowed to run the P98TAM application.  This application is the application where users specify which table they wish to open within UTB. Regards, JDEHelp This email may contain confidential or privileged information for the intended recipient(s).

How to recover a deleted package

If the  package was deleted from the Application P9601 but the directory still exist on the deployment server, this is what can be done in order to restore it:  1. Go to deployment server and rename the correspondent package name directory to a different name (just so it does not wipe it out) 2. Go to the package assembly and recreate it with the initial package name 3. Go to the package definition and also recreate it BUT don't check anything: uncheck all boxes, save and activate it 4. Rename the directory back to the initial package name on the deployment server. 5. Do a submit build . It will see that the directory is there, will ask if you want to delete it and say NO. 6. It will process it and actually, since everything was unchecked, it will not do anything but set the build status to complete/successful   Regards, JDEHelp This email may contain confidential or privileged information for the intended recipient(s). If you are not the intended recipient, please do not u

Solution for view PDF issue on web client

Hi all, Here are the settings to solve View PDF issue on web client. IE7 --> Internet Option --> click security tab--> go to click on Custom level --> Enable Active X control and plug-ins--> Download section Enable Automatic Prompting for file downloads. Regards, JDEHelp